Loading... Please wait...

Piezometers

Titanium Piezometer (VW) | Model 4500Ti

  • Model 4500Ti Titanium Piezometer with cable in stainless steel tube.
  • Model 4500Ti Titanium Piezometer with PVC jacketed cable.
SKU:
Model 4500Ti

The Model 4500Ti is designed specifically for use in highly corrosive environments such as landfills and leach fields. Also used in critical areas where long-term survivability is essential, for example, as in nuclear waste repositories and aggressive mine tailings. All exposed surfaces are made from titanium.*

Specifications

Standard Ranges¹
−100 to 350, 700 kPa; 1, 2, 3, 5, 7.5 MPa
Over Range
1.5 × rated pressure
Resolution
0.025% F.S. (minimum)
Accuracy
±0.1% F.S.
Linearity
<0.5% F.S. (±0.1% F.S. optional)
Temperature Range²
−20°C to +80°C
Length × Diameter
125 × 25.4 mm

¹Other ranges available on request.

²High temperature versions available on request.

*Please Note: All GEOKON vibrating wire piezometers include tripolar plasma surge arrestors to protect the sensor coils from possible lightning damage. Semiconductor piezometers are also available (see 3400 Series).

Please Note: Geokon maintains an ongoing policy of design review and reserves the right to amend products and specifications without notice. Various instruments are discontinued over time and replaced with new, updated models.

top