Loading... Please wait...

Pressure Cells

Semiconductor Type | Model 3500

  • Model 3500 Series Semiconductor Pressure Cells.
  • Model 3500 Earth Pressure Cell installed under railroad tracks.
SKU:
Model 3500

The 3500 Series is similar in design to the 4800 Series but the vibrating wire transducer is replaced by a semiconductor type transducer (to enable the measurement of dynamic pressures) which can have an output of 2 mV/V, 0-5 VDC or 4-20 mA. Typical applications are the measurement of traffic induced stresses on roadway sub grades, airport runways or under railroad tracks.

Specifications

Standard Ranges¹
100, 250, 400, 600 kPa; 1, 2.5, 6 MPa
Over Range
1.5 × rated pressure
Resolution
Infinite
Accuracy²
±0.25% F.S (0.1% F.S. available on request)
Temperature Range¹
−20°C to +80°C
Dimensions
Varies

¹Other ranges and sizes available on request.

²Transducer accuracy established under laboratory conditions.
Total system accuracy (pressure transducer + pressure cell) is subject to site-specific variables.

Compatible Readouts and Dataloggers

Please Note: GEOKON maintains an ongoing policy of design review and reserves the right to amend products and specifications without notice. Various instruments are discontinued over time and replaced with new, updated models.