  • Model 4150 Addressable Strain Gage, shown on soil nail.
    Addressable Vibrating Wire Interface
    The Model 8020-30 Addressable Interface is designed to “daisy-chain” vibrating wire sensors on a single 4-conductor cable, using the Modbus® RTU protocol over an RS-485 connection. It is particularly useful for reducing cable runs in...
  • Model 3810B Digital Temperature String.
    Digital Temperature Strings
    The Model 3810B Digital Temperature String is a variation of the Model 3810 Thermistor String, which uses temperature sensors installed on a 2-pair cable. This configuration allows up to 248* sensors to be installed on a single, 8 mm diameter cable...
  • Model 8020-59 Vibrating Wire Frequency to Analog Converter.
    Frequency to Analog Converter (VW)
    The Model 8020-59 Vibrating Wire (VW) to Analog Converter provides a simple way to connect GEOKON vibrating wire transducers to data acquisition systems, which are not capable of reading frequency signals nor able to generate the proper signals...
  • The Model 8920 Series includes the Cellular Addressable Data Logger, Cellular VW Data Logger and Cellular Tilt Logger (top, left to right),  and the 4- and 8-channel Cellular VW Data Loggers (bottom, left to right).
    GeoNet Cellular + Wi-Fi® Network Data Loggers
    The Model 8920 Series Cellular Data Loggers and Model 8930 Series Wi-Fi Data Loggers offer high-value, networked data collection options for all GEOKON vibrating wire instruments and addressable sensor strings.¹ The 8920 is ideal for smaller...
  • The Model 8921 Series Cellular Data Loggers include the Single-channel VW, Addressable, and Tilt Data Loggers (top, left to right), and the 8-channel VW, 4-channel Analog, and Digital High Power Data Loggers (bottom, left to right).
    GeoNet Cellular Data Loggers
    The Model 8921 Series Cellular Data Loggers offer high-value, LTE Cat 1 compatible, networked data collection for all GEOKON vibrating wire instruments and addressable sensor strings.¹ The 8921 Series data loggers are ideal for smaller networks...
  • Model 8960-01C-CBL, 8960-04C-CBL and 8960-08C-CBL (top left to right) GeoNet Digital Vibrating Wire Interfaces. Model 8960-01C-CAB Vibrating Wire Interface (lower left).
    GeoNet Digital Vibrating Wire Interfaces
    The Model 8960 Series Digital Vibrating Wire Interfaces expand the capacity of GeoNet Dataloggers, Mesh, Cellular, and Wi-Fi® Multi-Channel and Addressable Loggers by allowing users to add additional sensors to the system. The Model 8960 Series also...
  • Model 8940-01C-CBL, 8940-ADR-CBL, 8940-TLT-NAP GeoNet Data Loggers (top, left to right); Model 8940-04C-CBL and Model 8940-08C-CBL GeoNet Data Loggers (bottom, left to right).
    GeoNet Localized Data Loggers
    The Model 8940 Series GeoNet Data Loggers offer high-value, localized data collection options for all GEOKON vibrating wire instruments and addressable sensor strings¹. The Model 8940 Series are available in five options, including single-, 4- and...
  • The Model 8910 Series includes the LoRa Single-Channel VW Data Logger, 4-Channel Analog Data Logger, Single-Channel Addressable Data Logger, Time Domain Reflectometry (TDR) Data Logger,  Tilt Logger,  and Gateway (left to right).
    GeoNet Wireless LoRa® Data Acquisition System
    The GeoNet 8910 Series is a wireless data acquisition system and hosted data platform that utilizes LoRa radio technology. The integrated system comprises a gateway and subordinate wireless data loggers for efficient collection of sensor data from...
  • The Model 8800 and 8900 Series include the Mesh VW Data Logger, Mesh Addressable Data Logger, Mesh Tilt Logger and Local Gateway (top, left to right), the 4- and 8- channel Mesh VW Data Loggers and the Cellular Gateway (bottom, left to right, Model 8900 Series pictured).
    GeoNet Wireless Mesh Data Loggers
    The GeoNet 8800 and 8900 Series is a low-power, wireless data acquisition system and hosted data platform. The integrated system affords the efficient collection of sensor data from many points and provides secure access to sensor data via the...
  • The Model 404 Intrinsically Safe Vibrating Wire Readout.
    Intrinsically Safe Readout (VW)
    The Model 404 Intrinsically Safe Vibrating Wire Readout is a portable, low-power, hand-held unit, designed in cooperation with GEL Instrumentation, that is capable of running for more than 6 hours continuously on a single charge. The Model...